BY BILL DUN
Note: this information is presented without warantee or gaurantee to it's reliability or effectiveness. Nor does it imply that these methods will work or are the only ones possible.
Reprinted from the Commodore Club of Rockford Newsletter - March 1993
Code | Check These | Code | Check These |
---|---|---|---|
A | 6502 | E | LM311 |
B | 6522 | F | 582 |
C | 32530201 | G | 9602 |
D | 90122905 | H | 32557202 |
CHECK THESE | SYMPTOM | |||||||
---|---|---|---|---|---|---|---|---|
6502 | 6522 | 32530201 | 90122905 | LM311 | 582 | 9602 | 32557202 | |
A | C | D | ERROR LED STATUS ON ALL THE TIME | |||||
B | DRIVE MOTOR RUNS ALL THE TIME AND LED STAYS ON | |||||||
A | D | DRIVE MOTOR RUNS ALL THE TIME AND LED STAYS OFF | ||||||
B | AFTER WARM UP, MOTOR RUNS ALL THE TIME | |||||||
D | E | DOES NOT LOAD WHEN HOT OR LED FLASHES 3 TIMES | ||||||
D | SEARCHES WITH LED FLASHING CONTINUOUSLY | |||||||
C | SEARCHING WITH NO RED LED | |||||||
F | G | H | DRIVE FAILS TO READ | |||||
B | H | FAILS TO FORMAT DISK | ||||||
A | B | STEPPER MOTOR DOES NOT STEP FORWARD | ||||||
A | WILL NOT SAVE WHEN DRIVE HEATS UP | |||||||
D | LIGHTS STAY ON, MOTOR RUNS CONTINUOUSLY |