THE 1571 (and 1571 in the DCR) * COMMON PROBLEMS AND SOLUTIONS includes chips vs symptoms for the stand-alone 1571 drive latest changes and corrections 9-19-2022 I TAP ON THE DISK, THEN IT WORKS... This is such a common complaint, I put it here at the top of the list. Some users indicate that they must "tap on the disk after inserting it and closing the drive door" to get the drive to work properly. Some report that they can hear a "click" when they do that and then the drive works fine. This problem can be caused by: 1. a sticky lifter mechanism, (see HEAD LIFTER) or 2. the ejector mechanism is not latching properly (see DISK EJECTOR). DOOR LATCH: The twist down latch has a pin that eventually works loose and can fall out. That's what has happened if the latch flops around and will not move the mechanism. Hopefully, it's still in the drive (rattling around?) and can be recovered. If allowed to float around in there, it can short something out and cause damage. It's a round silver metal shaft, about 3/4" long and about 1/16" in diameter. If you can't find it after taking the drive apart, the correct sized nail can be cut to fit and installed as a replacement pin. The original, if still there, can be reinserted and secured with a dab of superglue or contact cement... just enough to keep it from sliding back out. It should be inserted just far enough to engage the white plastic part of the latch mechanism... too far forward, and it will scrape the metal part of the latch. Lube the metal-to-metal parts of the latch while you're at it. Another part of the door latch I've had problems with is the shaft of that mechanism pulling out of the assembly. When the door knob is pulled off, the shaft comes out with it! If that happens, you'll need to see what a properly assembled latch mechanism looks like to put it back together. I use a dab of superglue to hold it in place after assembly. Let it dry completely before you re-install it or some glue residue may migrate onto the rear plate and not allow the shaft to turn. HEAD WIRES: The top head moves up and down when a disk is inserted and the door latch is turned. The 5 connecting wires on the top head must be free to move, but such movement will cause them to break eventually. Some drives will have a bit of epoxy where the wires are soldered to act as a strain relief. Note: wires can still break -inside- the insulation where it can't be seen. If you pull -gently- on each one with tweezers, the broken ones will be loose and pull apart easily. Looking down on the drive head, with the front of the drive facing you, the color code of the wires is as follows, from left to right: green, red, white, yellow, black. If any of these wires are broken, the drive will still work in the 1541 mode (bottom head only is used), but in 1571 mode, the top head will not function properly. If any wires are broken, you will need to trim off some insulation from each wire and resolder it. Because the repaired wires will be a bit shorter, you should cut the ties holding the cable to allow more freedom of movement for the remounted wires. Form a small loop in the wires for maximum flexibility. Add a dab of epoxy or silicon sealer to the wire ends to allow them to flex without breaking again. Loosely tie the cable back to the head assembly. Open and close the drive door with a disk inserted to see if the wires have enough slack to allow complete head motion. If the wires are too tight, the head will not come all the way down to the disk surface, and you will create intermittant read/write problems. Also, if there is not enough slack in the wires, they will break again in a short time. When you complete the repair to the wires, tie the cable bundle back to the head with thread or string and a dab of glue. HEAD MOUNT: In a 1541 disk drive, the disk is pressed against the single read-write head by a felt pad. That spring-loaded pad is lowered onto the disk when the door latch is pressed down. In the 1571, when you insert a disk and lower the door latch, a head lifter mechanism releases, and the spring-loaded top head is gently lowered down onto the disk. Both heads thereby remain in intimate contact with both sides of the disk. The top head is mounted by means of two thin flexible metal strips. The metal is rather fragile and can be damaged by rough handling. Notice that the head has only one "finger" (on the left side) to allow the lifter mechanism to keep it raised. If shipped without a transit card or disk in place, the head mount can be subjected to excessive twisting force because all the weight of the head is on the finger. A downward shock can twist the head mount and can possibly break it. The top head must sit straight and line up with the bottom head. If the mount is bent or torn, the head will not sit straight. You may notice that a spinning disk makes more noise than it should... that's the sound of the top head scratching it. Depending on the severity of the misalignment, the drive may not be able to read the top side of a disk (blocks over 664), the drive may not work even in 1541 mode, and/or disks may be damaged. If the head mount is only slightly bent, it should be possible to straighten it by -gently- bending it back into proper alignment. Some users put weights (like a penny) on the top head, or increase the tension of the spring to provide more force. This is to be avoided... it will cause increased head and disk wear. It will not solve whatever problem it was meant to, and can cause further damage. Better to find out what is actually wrong, and fix that. See HEAD LIFTER HEAD LIFTER: This mechanism prevents the top head from lowering except: 1) when a disk is inserted, and 2) the door latch is down. It's there to keep the two heads from banging into each other. When a disk is inserted, it pushes a small lever with a brass cone-shaped end (at the left middle side of the drive) out from under the head lifter and allows the head to come all the way down and press on the disk. The brass cone should slide forward on the tab of the metal plate above it when a disk is inserted all the way, and should move completely out of the way when the door latch is closed. If the cone does not move far enough or if the metal plate is sticky, the lifter will prevent the top head from being lowered all the way down to the disk. The result may be intermittant operation of the drive in all modes, but especially in the 1571 double-sided mode, when data is accessed on the top side of the disk. It may take longer to read disks (the drive will try several times until it gets a good read), or you may encounter errors on that side of the disk. See if the cone-lever is sticking by pushing on it with a toothpick while lifting up on the lifter plate. The cone lever has a spring return and is hidden under the metal lifter plate when no disk is there. When you insert a disk and close the door slowly, see if the cone is pushed all the way back out of the way by the downward pressure of the spring-loaded plate. If not, see if the plate is free to move down by itself. Insert a disk, move the cone lever back out of the way and pull up on the plate with your finger, then gently release it. It should drop all the way down and release the head. If not, the lifter plate probably needs lube (oil) on both ends of the shaft. It's less likely, but the cone lever may need cleaning and/or lubrication if the lever itself is sticky, or it needs lube at the contact point of the cone and the tab. I prefer Molytone grease, available at electronics supply houses bit it's best if that cone is free of any kind of lube. I routinely lube the lifter plate hinge when I get a 1571 on the bench, whether it needs it right then or not. If someone tried to "adjust" the cone lever or the plate, one or both may be bent, and bending may be necessary to straighten them again. I would only try bending parts as a last resort!!! The cone should be pointing straight up and should be shiny with no burrs on it. The tab above it should likewise be clean. Examine its underside (the contact point for the brass cone) for burrs or rough spots. A pencil eraser works well as a polishing tool. If the drive has been "adjusted" by repair attempts, you may need to compare it to a working drive to see how everything -should- line up. Before you even think about bending anything in an attempt to fix your drive, consider this: the drive worked for years from the factory the way it was designed. Find out why it doesn't work and repair it correctly. An easy way to tell if the head is hanging up on the lifter is to observe the black plastic "finger" on the left side of the top head. With a disk in the drive and the door closed, that finger should -not- be touching the lifter mechanism at all. NOTE: some disks may be slightly smaller and not push the cone lever far enough. That's rare but it can happen. If more than one disk does that, suspect a problem with the mechanism. If it's marginal and the cone lever is not sticky, you can make an adjustment of the tab on the rear of the eject mechanism L-shaped slide plate. There are several small screws holding that plate and the mounting holes are elongated to allow for an adjustment. OPTICAL SENSORS: The 1571 has three infra-red activated sensors. If these sensors become contaminated with dust or smoke residue, it can cause the drive to malfunction. The TRACK ZERO DETECTOR is located at the right rear of the drive head assembly. It is used during disk Formatting, Initialize, and whenever the drive seeks track zero. If out of adjustment, contaminated, or defective, it may cause the drive to "chatter" like a 1541 when the stepper hits the mechanical head stop. Another failure mode allows the head to go all the way forward, chatter and stay there. The INDEX DETECTOR (just to the left of the spindle collar) checks the disk for the index hole. Although not needed on a Commodore GCR drive, this sensor maintains compatiblity with the MFM standard when the drive is used in that mode (the index hole conincides with sector 1). The WRITE-PROTECT SENSOR at the left front side of the drive senses disk change and write-protect status. It should be checked and/or cleaned if the drive will not format or write to a disk, but otherwise works normally. Don't forget to check for a write protect tab that may have fallen off a disk and got stuck at the sensor. Sensors can be cleaned with compressed air (to remove dust) and/or a Q-tip moistened (not wet) with alcohol (to remove residue from cigarette smoke). Do not remove the mounting screws to gain access to the sensors... you will upset their alignment. The index and write protect sensors are accessable through the drive door area with the front cover removed from the drive. The zero stop sensor is a tight fit. Remove about half the head from a Q-tip and it will work. You'll need to move the head forward to get to the sensor. DISK EJECTOR: This mechanism should automatically eject the disk when you open the drive door. Normally, when a disk is inserted, it pushes a spring-loaded slide plate back which locks in place. When the drive door is latched down, it triggers the release mechanism, and the plate remains fixed in place until the drive door is opened again. The slide plate then releases, the spring forces it backwards and it ejects the disk for the user to grasp. You can hear each one of these actions if you listen closely. If the drive does not automatically eject disks, check for a bent, misadjusted or sticking slide lever, or a missing, broken, or dislodged spring. Sometimes the lever releases prematurely when the drive door is closed. If that happens, you may hear a scraping sound as the spinning disk rubs the inside edge of the disk jacket. This problem can also cause a failure to read properly and can be "cured" by tapping on the disk after insertion and closing the door. You may hear the click of the ejector latching again. If the ejector is the problem, you can bend the slide plate down a bit at the spot where the tang on the slider engages the lower fixed plate. Don't bend it too far down or the slider will bind and disks will not eject at all. CLEANING AND LUBRICATION: The heads and stepper rails should be cleaned periodically, especially if the drive is running in a smoky or dusty atmosphere, or if old disks are used (shedding oxide onto the heads). Dust can be blown out with compressed air. Since the upper head is on a rather delicate swivil mount, a minimum of force should be used to clean it. Pull the top head up gently (it will not go very far before it hits the stop), just enough to get a Q-tip moistened with alcohol between the two heads. Rotate the Q-tip between your fingers to wipe the heads. The easiest access point is between the rails on the right hand side of the drive. A really stubborn head clog will require more effort to clean. One trick I use is a strip of white paper about 3/4" wide and 6" long. The upper head will not go all the way down unless a disk is in the drive because of a spring-loaded cone-lever, so that must be moved out of the way so the top head will drop all the way for cleaning. See HEAD LIFTER above. Position the paper strip between the heads, push down gently on the upper head and draw the paper out. If you see a smear on the paper, that was some residue that came off one or both heads. Note: if a 1571 format only works on one side of a disk, the upper head is suspect and may need cleaning. Alcohol works OK for heads, but a stronger solvent should be used on the stepper rails, especially if they are contaminated and/or sticky with old grease. I use WD40 as a solvent, but caution must be used not to get any solvent on plastic parts as it may attack the surface. Swab down the rails and move the head assembly gently back and forth (drive turned off, of course) to reach further into the tight spots. Alternate between swabbing and moving the assembly several times until the rails are clean. You can't get everywhere, but with solvent on the rails, just moving the stepper back and forth will dislodge the dirt and old grease that can then be wiped off. Let the solvent dry throughly. Although it's really not necessary, you can relube the rails using a small amount of silicone or graphite lube, or just run them dry. Don't use oil... it will attract dirt and get sticky again. ROM BUG: If your stand-alone (not the 128DCR drive) 1571 takes a long time to access a 1541 formatted disk, suspect the early version drive ROM 3.0 (CBM # 310654-03) as the reason. If you're on the fence regarding adding JiffyDOS to your system, here is one more reason... it corrects that bug. If you want the original upgraded CBM ROM (although it still shows as version 3.0 when quiried) and have access to a burner, the part number is 310654-05. The one used in the USA C128DCR (metal case) is version 3.1 with CBM part number 318047-01. There are differences between the two ROMs (1571 and 1571DCR) and they should not be used interchangeably, but I have for test purposes only. POWER SUPPLY: The power pack inside the 1571 uses a switching type of supply. It runs cool and rarely fails. If it does malfunction, it can be replaced easily (one plug-in connector) or repaired by a competant technician. If you disconnect the power supply, make sure you note how the connector is oriented. If it is installed backwards, it will cause severe damage to the supply and/or the drive electronics package. The four-pin plug of the supply goes to a motherboard socket: CN1. Pin # 1 is marked on the board. The correct orientation of the PS plug is: pin 1 = black, pin 2 = brown, pin 3 = black, pin 4 = red. It's wise to somehow mark any connectors you remove to prevent mistakes when you put them back. OTHER PROBLEMS: Because it runs cooler than a 1541, the 1571 rarely fails because of chip problems. In the rare event of a malfunction, one thing you can try is reseating the only socketed chip in the drive: the DOS ROM, a 310654-03 at board location U3 on the drive controller board (under the power supply). The power supply (metal can) can be moved out of the way (four screws) without disconnecting it. It will just fold up and over the drive mechanics, but be mindful that the power connector may be unplugged when you do that. Make sure you know how it goes back... don't get it backwards! If any other chips are socketed (perhaps because the drive was repaired before), try reseating them too. Make sure the connections between the drive and motherboard are properly seated when you're finished. Remove and reinsert them to clean the contacts. The mechanism for the stand-alone 1571 and for the internal drive in the 128D are the same, although I've heard that some will require cutting a bit of the cabinet at the drive latch because it rubs on the latch shaft. Drives can be interchanged if necessary as a diagnostic or to salvage a working mechanism from a bad drive. Added notes for the 1571D (drive inside the USA C128DCR): The socketed DOS ROM in the 128DCR is under the drive mechanism on the motherboard at location U102. It's different than the version 3.0 in the stand-alone 1571 and in the European C128D (plastic case). The one in the USA DCR drive electronics is DOS version 3.1. That's important if you want to get JiffyDOS to replace the DOS ROM. If there is a problem with the drive in the C128DCR, you may get "dumped" into the built-in monitor at boot time (when it tries to autoboot). If that happens, the screen will show something like: U1:13 0 01 00. If you are having problems with internal drive access, as a diagnostic, or to use an external drive as device 8, you can disable the internal drive by disconnecting the ATN line, pin 1 of IC U113 (74LS14). That will make the internal drive "invisible" to the computer. That IC is under the drive near the right front edge of the computer. If you cut the IC pin, leave enough of a stub so that you can solder it back if necessary (cut it close to the motherboard). CHIPS VS SYMPTOMS A normal startup sequence is as follows: with drive disconnected from computer, power up shows a continuous red power LED, and the green status LED comes on and goes out within about 1 second. The spindle motor runs for about three seconds and then stops. The stepper moves the head slightly back and forth, then stops. Note that the spindle motor may continue to spin if the computer is connected but turned off... that's normal because it holds the reset line. Also normal is spindle running about 10 seconds after disk reads. When the drive startup sequence or other operation is not normal, this information might help nail the problem down. I assume you have already checked the power supply for its +5 and +12 volt DC outputs. Note: when connected to a 128, the drive will attempt to auto-boot only if the drive is set to device 8! U1 (DCR U101) MPU 6502 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. U2 (DCR U102) DOS ROM 310654-03 (upgrade -05 or DCR #318047-01) Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. U3 (DCR U103) SRAM M2128-xx or TMM2016 When powered up, green LED flashes once per second continuously. No drive access, locks up computer. U4 (DCR U104) VIA, SPINDLE MOTOR CTRL 6522 Green LED stays dark at power up and spindle motor runs continuously. No drive access, locks up computer. U5 MASTER OSC 251829-01 Drive powers up normally but no read, DRIVE NOT READY error. (DCR U105 GATE ARRAY) U6 CONTROLLER 251828-01 OR HD61J215P Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. (DCR U106 6522, VIA SERIAL INTERFACE) U7 HEAD AMP & STEPPER CTRL 251853-01 or M36A2U57 (DCR U107 CPU 5710) U8 logic 7406 Normal looking startup (LEDs and motors) and computer resets drive but no access, 74 DRIVE NOT READY error. (DCR U108 HEAD AMPLIFIER, CX20185 SURFACE MOUNT IC) U9 VIA 6522 Normal looking startup (LEDs and motors) but no drive access although computer resets drive when turned on or reset, locks up computer. (DCR U109 STEPPER DRIVER uPA2003C) U10 logic 74LS74 Normal looking startup (LEDs and motors) and read OK but no write or format. U11 DISK CONTROL WD1770 or WD1772 Normal looking startup (LEDs and motors) but when computer boots, drive can't read disk and stepper moves head to track zero. Subsequent disk access shows 74 DRIVE NOT READY error and green LED flashes rapidly. NOTE: this bad IC can corrupt disks! U12 logic 74F32 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. (DCR U112 7606 SERIAL INTERFACE LOGIC) U13 logic 74LS266 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. U14 logic 7407 Normal looking startup but no read in 1571 mode, reads in 1541 mode but no write or format (21 READ ERROR). Can also cause disk ID mismatch after disk swap. (DCR U114 74LS14 SERIAL INTERFACE LOGIC) U15 logic 74LS14 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. Computer locks up. U16 logic 7406 Normal looking startup but spindle doesn't run. Although computer resets drive, access shows DEVICE NOT PRESENT error. U17 logic 74LS14 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. Computer locks up. U18 logic 74LS175 Green LED on steady and spindle motor runs all the time, no movement of the stepper at turn on. No drive access, locks up computer. U19 logic 74LS241 Normal startup but 1541 mode only (read, write, format OK), no 1571 mode. U20 CIA 6526A or 8521 No 1571 mode but normal startup, read, format and write in 1541 mode only. U21 RESET GENERATOR T520D U22 logic 74LS123 Normal startup and read/write but format fails and locks up computer. Y1 XTAL OSC TCO-745A Ray Carlsen Carlsen Electronics Questions and comments are welcome, especially if you spot a mistake here. Thanks!